DIN Rail DC UPS

Newmar DIN Rail DC UPSThe Newmar DIN Rail DC UPS, 12V, 24V and 48V DC, powers loads and charges the back-up battery and is ideal for security, wisp, wireless systems, transmitter and enclosure applications.

DIN Rail DC UPS Features

  • Combines all system power functions: power supply, battery charger, UPS circuitry and status monitoring in one compact DIN rail mount unit
  • Dual outputs for load and battery:
    • “Load priority” output distribution ensures power is dedicated first to the load, with remainder then allocated to battery charging, thus preventing a discharged battery from impacting operation of critical loads.
    • 3-step charging for rapid battery recovery, programmable for battery type, with optional temperature compensation sensor
  • Battery automatically supports load anytime AC fails
  • Low voltage disconnect prevents total battery discharge
  • Operates from street light voltage – 277V AC
  • Automatic periodic battery health diagnosis
  • High operating temperature range to 70˚ C
  • Alarm contacts: AC fail, battery at risk
  • Communication MODBUS via RS-485 interface (DIN-UPS 48-10, DIN-UPS 24-20, and DIN-UPS 12-35 models only)
  • CE Approved/Designed to UL 1950

DIN Rail DC UPS Specifications

ModelOutputMODBUSDimensionsWeight
VoltagePower(H x W x D)
DIN-UPS 12-10*12 VDC10 AmpsNA4.5″ x 2.6″ x 5.3″2 Lbs.
DIN-UPS 12-3512 VDC35 AmpsYes4.5″ x 5.9″ x 5.3″4 Lbs.
DIN-UPS 24-1024 VDC10 AmpsNA4.5″ x 3.9″ x 5.3″2 Lbs.
DIN-UPS 24-2024 VDC20 AmpsYes4.5″ x 5.9″ x 5.3″4 Lbs.
DIN-UPS 48-548 VDC5 AmpsNA4.5″ x 3.9″ x 5.3″2 Lbs.
DIN-UPS 48-1048 VDC10 AmpsYes4.5″ x 5.9″ x 5.3″4 Lbs.

Additional Specifications

Front Panel LED Indicators: Power Source: AC or on back up and Battery and System Diagnostics (via blink code)

Settings/Selectors:

  • Battery Type: Lead Acid, Gel-Cell
  • Battery Charge Current Limit: 20 – 100% of charge amperage rating
  • Back-Up Run Time on Batteries: Programmed time limit: 1 – 60 min. (DIN-UPS 48-10, DIN-UPS 24-20, and DIN-UPS 12-35 models only), or until LVD disconnect
  • Power Restore Button: connects battery without AC present

Signal Outputs (form C):

  • AC Fail – operating on back-up power
  • Battery abnormal condition (summary contact): Discharged, damaged, disconnected, sulfated/ short circuit, reverse polarity, bad thermal sensor
  • MODBUS Communication (DIN-UPS 48-10, DIN-UPS 24-20, and DIN-UPS 12-35 models only)

Temperature: -25 to +70˚ C. Continuous to 50˚, de-rate 2.5% per ˚C >50˚ C
Cooling: Free air, convection
Reliability (MTBF): 300,000 hours
Efficiency: 91%

Optional Accessories

  • Battery temperature sensor: 100 feet or 3 foot cable lengths
  • Parallel Connection for Redundancy: DIN-UPS units can be paralleled for 1+1 redundancy to obtain a higher system availability. Redundant systems require a certain amount of extra power to support the load in case one DIN-UPS unit fails. The simplest way is to put two DIN-UPS in parallel.
 

For more information about Newmar DC Power products,