The Schneider Electric Uniflair Ceiling Mounted Split, for Room Air Conditioning, is a space-saving, overhead precision cooling system that offers high efficiency. 

Uniflair SP systems are split systems, meaning the evaporator and condenser are installed separately. The evaporator unit is designed to be installed on the ceiling or wall, while the condenser portion of the unit is mounted outside. Designed for ease of service, a different access is given for the electrical board, mechanical compartment, and fans. This means that calibration and servicing can be carried out safely. These units are available in free cooling configuration, that when activated, enables the use of outside air to help cool the IT environment saving money for a better bottom line.

Uniflair Ceiling Mounted Split Features

  • Active response control, monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures
  • Direct Free Cooling, utilizes outdoor air when ambient air temperature can help support cooling loads
  • Scroll compressors, few moving parts for increased reliability and life expectancy
  • Dual power inputs (optional), dual power supplies for incoming power redundancy
  • Network interface provides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH
  • Building management system integration, send alarms and data points allowing you to manage critical building infrastructure from a single system
  • Microprocessor controller, provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display
  • The monitoring devices on board the unit allow for preventive maintenance and a check of the working condition of the system while its in operation
  • Easy service access 
  • Units are made of two separate sections: the evaporation section, which is installed inside the conditioned room (UCA – UCF), and the condensation section (MRA), which is installed on the outside

Ceiling Mounted Split Specifications

  • Power supply: 230 V/1/0 Hz or 400 V/3+N/50 Hz (Standard, according to the model)
  • Main power supply + UPS, 48 VDC (evaporator DC-fan/s)
  • Evaporator sections are equipped with: Microprocessor control, EU4 filter (optional), Scroll compressor, Modulating condenser fan/s speed control