{"id":4800,"date":"2014-01-23T10:00:20","date_gmt":"2014-01-23T15:00:20","guid":{"rendered":"http:\/\/alphaenertech.com\/?p=4800"},"modified":"2018-04-09T10:11:27","modified_gmt":"2018-04-09T14:11:27","slug":"3-tips-to-improve-the-efficiency-of-high-density-server-racks","status":"publish","type":"post","link":"https:\/\/alphaenertech.com\/2014\/01\/23\/3-tips-to-improve-the-efficiency-of-high-density-server-racks\/","title":{"rendered":"3 Tips to Improve the Efficiency of High Density Server Racks"},"content":{"rendered":"
\n\n\n\n
\n
\n\n\n\n
\n
\n\n\n\n
\n
\n\n\n\n
\n

<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n

<\/p>\n

<\/span><\/p>\n

\n\n\n\n
\n
\n\n\n\n
\n
\n\n\n\n
\n
\n\n\n\n
\n

<\/p>\n

<\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n

<\/p>\n

<\/span><\/p>\n

\n\n\n\n
\n
\n\n\n\n
\n
\n\n\n\n
\n
\n

\"Alpha<\/p>\n

<\/span><\/p>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n

<\/p>\n

<\/span><\/p>\n

\n\n\n\n
\n

<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/td>\n

\n
\n\n\n\n
\n
\n\n\n\n\n
\n
\n

January, 2014 – In This Issue:<\/p>\n

<\/span><\/i><\/b><\/p>\n<\/div>\n<\/td>\n<\/tr>\n

\n\n\n\n\n\n
\n
\n
\n
\n

Avoid Data Center Hot Spots with Proper
\nCable Management<\/span><\/a><\/p>\n

<\/span><\/b><\/p>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n

<\/p>\n

<\/span><\/p>\n

\n\n\n\n
\n
\n\n\n\n
\n

<\/p>\n

<\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n

<\/p>\n

<\/span><\/p>\n

\n\n\n\n
\n\n\n\n
\n

<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n

<\/p>\n

<\/span><\/p>\n

\n\n\n\n
\n


<![if !supportLineBreakNewLine]>
\n
<![endif]><\/p>\n

<\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n

<\/a><\/p>\n

<\/span><\/p>\n

\n\n\n\n
\n

<\/a>\"HybridPower\"<\/span><\/p>\n

<\/span><\/p>\n

\n
\n

3 INEXPENSIVE WAYS TO IMPROVE THE EFFICIENCY OF YOUR
\nHIGH DENSITY RACKS<\/span><\/b><\/p>\n

<\/span><\/p>\n<\/div>\n

\n

Simple Tips to improve efficiency in your Network
\nCloset or Data Center<\/p>\n

<\/span><\/p>\n<\/div>\n

<\/p>\n

<\/span><\/p>\n

The power
\ndensity of data center racks and network closets has been rapidly
\nincreasing in recent years.\u00a0 In 2010, a typical data center rack
\ncontained 1.7kW of load whereas today, its not unusual to see 10kW or
\nmore in high density applications.\u00a0 Increased utilization of the
\ncloud and virtualization has translated to higher computing demands
\nfor many sites which means data centers and network closets need to
\nhouse and support more servers.\u00a0 With the growing popularity of
\nhigh efficiency blade servers, rack density has increased to
\npreviously unimagined loads.\u00a0\u00a0 The biggest challenge this
\nhas created is cooling the rack.\u00a0 Traditional CRAC configurations frequently fail to adequately support high density loads.<\/p>\n

<\/span><\/p>\n

<\/p>\n

<\/span><\/p>\n

Most of our
\ncustomers don’t have the budget to completely reconfigure their data
\ncenter architecture and adopt large scale cooling solutions such as InRow cooling or hot aisle containment in the short term.\u00a0 So, we’ve provided three simple and
\ncost-effective tips to help inexpensively control the environment for
\nyour high density equipment.<\/p>\n

<\/span><\/p>\n

<\/p>\n

<\/span><\/p>\n

\n
\n

1. Maximize airflow with Cable
\nManagement<\/span><\/strong><\/p>\n

<\/span><\/p>\n<\/div>\n

\n

Proper cable management does more than keep things tidy.\u00a0 Inadequate cable management
\ncan not only lead to damaged cables or increased time to add or
\nchange out cables, but can block critical airflow or access. This can
\nlead to inefficiencies in the performance of your equipment or even
\ndowntime.\u00a0 Cable Management parts and accessories are relatively inexpensive and are simple to install.\u00a0
Read more<\/a> about the importance of Cable Management<\/p>\n

<\/span><\/p>\n<\/div>\n<\/div>\n

<\/p>\n

<\/span><\/p>\n

\n

2. Control Hot Spots with
\nSupplemental Cooling<\/span><\/strong>
\nRack-based cooling products are specifically integrated in or on individual rack
\nenclosures to solve inadequate air distribution problems. Quick and
\neasy to deploy, Rack Air Distribution systems work with existing cooling products to either provide cool
\nair to or remove heat from the rack enclosure. Various hot air
\nremoval systems, fans, and rack air distribution systems are
\navailable to help minimize hot spots and ensure uniform inlet
\ntemperatures to the IT equipment.<\/p>\n

<\/span><\/p>\n<\/div>\n

<\/p>\n

<\/span><\/p>\n

3.
\nMonitor the environmental conditions of your racks with NetBotz<\/span><\/strong><\/p>\n

<\/span><\/p>\n

NetBotz<\/a> offers a
\ncost effective approach to environmental monitoring.
NetBotz<\/a> monitors
\nhumidity, temperature, door contact and dry contact, and other
\nenvironmental conditions remotely over your network. Additional
\nfeatures like user-defined alerts make the
NetBotz 200<\/a> the
\nperfect unit to protect your IT assets from environmental threats.
NetBotz<\/a> is highly
\nconfigurable and can be used in both Network Closets and Data
\nCenters.<\/p>\n

<\/span><\/p>\n


\nIncreased computing capacity and smaller, more energy efficient
\nservers are increasing rack density in many network closets and data
\ncenters.\u00a0 To ensure proper operation of your equipment and
\nultimately prevent downtime, it is essential to provide sufficient
\nairflow and cooling to your racks.\u00a0 Server manufacturers are
\nworking on technologies that internally cool the chips installed in
\ntheir servers, but until those internally cooled products are
\nmainstream, it will be up to the data center manager to maintain
\nproper operating temperatures with external cooling.<\/p>\n

<\/span><\/p>\n

<\/p>\n

<\/span><\/p>\n

Power
\nSolutions carries a complete line Cable Management, Rack Air Distrbution,
\nand
Environmental
\nMonitoring<\/a> products from manufacturers such as APC by Schneider
\nElectric, Eaton, Server Technology, and Middle Atlantic.\u00a0 Visit
\nour
website<\/a> for more
\ninformation or
contact me<\/a>.<\/p>\n

<\/span><\/p>\n

<\/p>\n

<\/span><\/p>\n

Sincerely,<\/p>\n

<\/span><\/p>\n

<\/p>\n

<\/span><\/p>\n

Guy Lacerte<\/p>\n

<\/span><\/p>\n

Power
\nSolutions, LLC<\/p>\n

<\/span><\/p>\n

86 21 5859 8677 ext. 702<\/p>\n

<\/span><\/p>\n

<\/p>\n

<\/span><\/p>\n

glacerte@alphaenertech.com<\/span><\/a><\/p>\n

LEARN
\nMORE<\/span><\/b><\/a><\/p>\n

<\/span><\/p>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n

<\/p>\n

<\/span><\/p>\n

\n\n\n\n
\n\n\n\n
\n

<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n

<\/p>\n

<\/span><\/p>\n

\n\n\n\n
\n
\n\n\n\n
\n
\n
\n

<\/a>HIGH
\nDENSITY OUTLET TECHNOLOGY (HDOT) PDUs<\/span><\/strong><\/p>\n

<\/span><\/p>\n<\/div>\n

\n

New innovation from Server Technology for high density
\napplications<\/span><\/p>\n

<\/span><\/p>\n<\/div>\n

\n
\n


\nGet up to 42
\nC13 outlets in a single 42U high x 1U wide PDU<\/span><\/strong><\/p>\n

<\/span><\/p>\n


\n<![if !vml]>
\n
\n<![endif]>
\nHigh
\npower densities and reduced cabinet space require innovative
\nsolutions to maximize every rack U of space in the data center.
\nWith Server Technology High Density Outlet Technology (HDOT) vertical PDU’s, you can have
\nthe highest possible outlet density available in a network connected
\nPDU.\u00a0 With HDOT PDU’s, you
\nget more C13 and C19 outlets while saving valuable rack space for
\ncable management and cooling.\u00a0 Manufactured with robust high
\ntemperature materials carrying a UL94 V-0 flame rating, the HDOT high
\ndensity PDU’s are suitable for the harsh data center environments.<\/p>\n

<\/span><\/p>\n

<\/p>\n

<\/span><\/p>\n

Server
\nTechnology HDOT PDU’s are
\navailable in Single Phase, Three-Phase 208V, and Three-Phase 400V in
\nMetered and Smart models and include these standard features:<\/p>\n

<\/span><\/p>\n